DB Series · fan controller

DB2 VFD Fan Controller

Smart airflow, lower energy costs. Ten speed levels and a temperature-based 0–10 V output, in an IP66 unit that is set up on the barn wall or from anywhere.

Photo for reference only. The actual product may vary.
Overview

One controller for the whole fan line

The DB2 is the ventilation controller at the head of the fan circuit. It reads barn temperature, moves along ten speed levels and drives variable-frequency fans through a 0–10 V analogue output — so airflow tracks the barn instead of running flat out from morning to night.

  • Temperature-based 0–10 V analogue output for VFD fans
  • A switched enable output alongside — run as well as how fast
  • Ten selectable speed levels, tuned from the front panel
  • IoT / Local / Off mode selector — ventilation runs without a network
  • IP66 enclosure, 290 × 190 × 110 mm, −20 to +80 °C
  • 10Selectable speed levels
  • 0–10 VTemperature-based analogue output
  • IP66Barn-ready enclosure
  • 3Mode choices — IoT, Local, Off
Advantages

Why the DB2 is specified

Four points straight off the DB2 brochure — and the reason it ends up on the wall of a fan line.

Automatic fan control

DB2 adjusts fan speed automatically as barn temperature changes.

Ten speed levels

Selectable stages keep airflow stable and easy to tune.

Local or remote

Set strategies on-site or through the BARNEYE IoT platform.

IP66 barn-ready enclosure

Protected for demanding, humid dairy environments.

Operation

How it works

Read, decide, control — repeated every time the barn temperature moves.

  1. 01 Read Barn temperature is the only input the controller needs at this grade.
  2. 02 Decide The DB2 selects the right speed level for that reading.
  3. 03 Control A 0–10 V signal drives the variable-frequency fan to that speed.
Configuration

Three positions on the selector

Remote when the network is there, local when it is not, and a clean way to stop.

  1. IoT Remote status and strategy updates from any web-enabled device.
  2. Local Straightforward front-panel operation when a network is unavailable.
  3. Off Safe shutdown — the third position on the selector.
Key specifications

Key specifications

ParameterSpecification
Input voltage100–240 V AC / 48–52 V DC
Input current0.21 A max.
Analogue output1 × 0–10 V
Switch output1 × enable (relay)
Mode selectorIoT / Local / Off
CAN bus1 × CAN input
RS-4852 × Modbus outputs
Ethernet1 × IEEE 802.3 port
Ingress protectionIP66
Dimensions290 × 190 × 110 mm
Operating range−20 to +80 °C

Planning a ventilation upgrade?

Send us the fan schedule and the barn dimensions. We will tell you how many DB2 units the fan line needs, how the fans should be grouped, and what the speed curve should look like for your climate.

Ask an engineer
Datasheet and wiring diagram
Mounting and coverage plan
Spares and service intervals